Line 33: Line 33:
 The stock firmware has a recovery mode triggered by holding down the reset button on power-up or hitting escape at the serial console. The recovery interface is accessible via HTTP at 192.168.1.10. The OpenWrt ''factory'' image is compatible. The stock firmware has a recovery mode triggered by holding down the reset button on power-up or hitting escape at the serial console. The recovery interface is accessible via HTTP at 192.168.1.10. The OpenWrt ''factory'' image is compatible.
  
-The version of U-Boot on the device is seriously crippled. It does not (apparently) have command-line prompt. Thus, firmware flashing is done only via the existing firmware or the aforementioned recovery mode. +When connected to the serial console, it is possible to drop into u-boot prompt by hitting 'q' in recovery mode. Note that there is no saved u-boot environment on flash, so you will have to set e.g. ''serverip'' every time you need to use TFTP.
  
 ===== Hardware ===== ===== Hardware =====